JX7100D Veterinary Anesthesia Machine
Product Parameters
- Number:
- VM4
- Specifications:
- 暂无规格
- Type:
- 暂无类型
- Attribute:
- 暂无属性
Introduction
It is a good veterinary anesthesia machine
- Configuration
- Function Introduction
- Instructions
Gas Supply:
Gas Source: O2,or O2&Air(Option), or O2&N2O(Option);
Gas Source Pressure Gauge: O2,or O2&Air(Option), or O2&N2O(Option);
Pressure of Pipeline Inlet:
O2,280kPa~600kPa/41Psi~87Psi, less than 180L/min;
N2O(Option),280kPa~600kPa/41Psi~87Psi,less than180L/min;
Air(Option),280kPa~600kPa/41Psi~87Psi, less than 180L/min;
Security Valve: release pressure less than 10 kpa;
O2 Lost Alarm(Option):Sound alarm, alimumun cylinder with whistle;
N2O cut off valve protection(Option): when O2 is lost, N2O will be cut off.
Flow Meter:
2 tubes high precision flow meter,0~1L/min,1.1L/min~10L/min; or 0L/min~10L/min(O2&Air or O2&N2O);
Precision: At 20 degree, atmospheric pressure is 101.3kPa, the precision of flow meter is level:2.5;
O2&N2O Linkage Device(O2&N2O,Option):make insure O2 concentration is not lower than 25%;
O2 Flush: 35L/min~75L/min;
One Key Switch: Switch between rebreath and Non-Rebreath;
ACGO Port: Non-Rebreath;
Selectatec Mounting Bar: single place used for vaporizer, it is easy to replace;
Anesthesia Vaporizer:one of Isoflurane/Halothane/Sevoflurane;
Respiration System/CO2 Circle Absorber/Rebreath:
Soda Lime Chamber: 800ml or 1600ml(Option);
Pop Off Vlave: with one key to close; APL valve(Option): 0.19~6kPa;
Airway Pressure Gauge:-20-100cmH2O;
Dimension&Weight:
Table Top:Width*Deepth*Height:57cm*25cm*40cm,22kg;
With Trolley: 55cm*56cm*132cm,40kg;
Gas Source: O2,or O2&Air(Option), or O2&N2O(Option);
Gas Source Pressure Gauge: O2,or O2&Air(Option), or O2&N2O(Option);
Pressure of Pipeline Inlet:
O2,280kPa~600kPa/41Psi~87Psi, less than 180L/min;
N2O(Option),280kPa~600kPa/41Psi~87Psi,less than180L/min;
Air(Option),280kPa~600kPa/41Psi~87Psi, less than 180L/min;
Security Valve: release pressure less than 10 kpa;
O2 Lost Alarm(Option):Sound alarm, alimumun cylinder with whistle;
N2O cut off valve protection(Option): when O2 is lost, N2O will be cut off.
Flow Meter:
2 tubes high precision flow meter,0~1L/min,1.1L/min~10L/min; or 0L/min~10L/min(O2&Air or O2&N2O);
Precision: At 20 degree, atmospheric pressure is 101.3kPa, the precision of flow meter is level:2.5;
O2&N2O Linkage Device(O2&N2O,Option):make insure O2 concentration is not lower than 25%;
O2 Flush: 35L/min~75L/min;
One Key Switch: Switch between rebreath and Non-Rebreath;
ACGO Port: Non-Rebreath;
Selectatec Mounting Bar: single place used for vaporizer, it is easy to replace;
Anesthesia Vaporizer:one of Isoflurane/Halothane/Sevoflurane;
Respiration System/CO2 Circle Absorber/Rebreath:
Soda Lime Chamber: 800ml or 1600ml(Option);
Pop Off Vlave: with one key to close; APL valve(Option): 0.19~6kPa;
Airway Pressure Gauge:-20-100cmH2O;
Dimension&Weight:
Table Top:Width*Deepth*Height:57cm*25cm*40cm,22kg;
With Trolley: 55cm*56cm*132cm,40kg;